European Style Square Body–General

Characteristics

Designed and tested to:

IEC 269: Part 4

UL Recognized

Minimal energy let-thru (I2t)

Low operating temperature

Low Watts loss

General Information

Each European Style fuse is available with a number of different end fittings. Options include:

DIN 43 653

North American Slotted Blade

DIN 43 620

Flush End (Metric/U.S.)

French Style

 

DIN 43 653–10-400 Amps.

Voltage Rating: 660V (IEC) & 700V (UL)

Interrupting Rating: 300kA RMS
Symmetrical.

Watts loss provided at rated current.

Microswitch indicator ordered separately.

Datasheet(s): 720013

 

DIN 43 653–40-2000 Amps.

Voltage Rating: 660V (IEC) & 700V (UL)

Interrupting Rating: 300kA RMS
Symmetrical.

Watts loss provided at rated current.

Microswitch indicator ordered separately.

Datasheet(s): 720014 and 720015

 

DIN 43 653–40-2000 Amps.

Voltage Rating: 660V (IEC) & 700V (UL)

Interrupting Rating: 300kA RMS
Symmetrical.

Watts loss provided at rated current.

Microswitch indicator ordered separately.

Datasheet(s): 720014 and 720015

 

DIN 43 653–50-1400 Amps.

Voltage Rating: 1250V

Interrupting Rating: 300kA RMS
Symmetrical.

Agency Information: UL Recognition&emdash;contact
Bussmann.

Watts loss provided at rated current.

Microswitch indicator ordered separately.

Datasheet(s): 720014 and 720015

 

DIN 43 653–50-1400 Amps.

Voltage Rating: 1250V

Interrupting Rating: 300kA RMS
Symmetrical.

Watts loss provided at rated current.

Microswitch indicator ordered separately.

Datasheet(s): 720029 and 720030

 

DIN 43 620–10-315 Amps.

Voltage Rating: 660V (IEC/UL)

Interrupting Rating: 300kA RMS Symmetrical.

Rated Current: The rated current of this fuse
range has been given with copper conductors that have a current density of 1.3 A/mm2
(IEC 269-4). For conductor cross section
according to IEC 269-1, the fuses with a rated current higher than 125A must be derated.
Please contact Bussmann for application
assistance.

Watts loss provided at rated current.

Microswitch indicator ordered separately.

Datasheet(s): 720016

 

DIN 43 620–40-1000 Amps.

Voltage Rating: 660V (IEC/UL)

Interrupting Rating: 300kA RMS
Symmetrical.

Rated Current: The rated current of this fuse
range has been given with copper conductors that have a current density of 1.3 A/mm2
(IEC 269-4). For conductor cross section
according to IEC 269-1, the fuses with a rated
current higher than 125A must be derated.
Please contact Bussmann for application
assistance.

Watts loss provided at rated current.

Microswitch indicator ordered separately.

Datasheet(s): 720017

 

Flush End Contact 25-400 Amps.

Voltage Rating: 660V (IEC)

Interrupting Rating: 300kA RMS Symmetrical.

Watts loss provided at rated current.

Microswitch indicator ordered separately.

Datasheet(s): 720018

 

Flush End Contact 40-2000 Amps.

Voltage Rating: 660V (IEC) 700V (UL)

Interrupting Rating: 300kA RMS Symmetrical.

Watts loss provided at rated current.

Microswitch indicator ordered separately.

Datasheet(s): 720019

 

Flush End Contact–1000-4000 Amps.

Voltage Rating: 660V (IEC) 700V (UL)

Interrupting Rating: 300kA RMS Symmetrical.

Watts loss provided at rated current.

Microswitch indicator ordered separately.

Datasheet(s): 720020

 

Flush End Contact–50-1400 Amps.

Voltage Rating: 1250V

Interrupting Rating: 300kA RMS Symmetrical.

Agency Information: UL Recognition&emdash;contact Bussmann.

Watts loss provided at rated current.

Microswitch indicator ordered separately.

Datasheet(s): 720031

 

French Standard–40-1500 Amps.

Voltage Rating: 660V (IEC), 700V (UL)

Interrupting Rating: 300kA RMS Symmetrical.

Watts loss provided at rated current.

Microswitch indicator ordered separately.

Datasheet(s): 720022

 

US Standard–40-2000 Amps.

Voltage Rating: 660V (IEC), 700V (UL)

Interrupting Rating: 300kA RMS Symmetrical.

Watts loss provided at rated current.

Microswitch indicator ordered separately.

Datasheet(s): 720023

 

US Standard–50-1400 Amps.

Voltage Rating: 1250V

Interrupting Rating: 300kA RMS Symmetrical.

Agency Information: UL Recognition&emdash;contact Bussmann.

Watts loss provided at rated current.

Microswitch indicator ordered separately.

Datasheet(s): 720032

 

Indicator System

Typower Zilox fuses are available with three different indicator systems.

Visual Indicator

The indicator situated in one cover plate is clearly visible as soon as the fuse has operated. The minimum voltage for operating the indicator is 20V.

Type T Indicator

Indicator on one cover plate and a tag on the coverplate for clip-on fitting of an auxiliary switch. The minimum voltage for operating the indicator is 20V. A special low voltage indicator (1.5V) is available on request.

Type K Indicator

This indicator is situated on the fuse body. It is covered by an adaptor for snap-on mounting of an auxiliary switch. The operating voltage of the indicator is 1.5V. As a matter of safety, the factory mounted adaptor must not be removed from the fuse.

Datasheet(s): 720034 and 72035

 

European Fuseblocks

DIN 43 653 Fuse Base 

For the Typower ZILOX fuses according to DIN 43 653, please contact your local Bussmann Sales Representative.

Universal Fuse Bases 

DIN 43 620 Fuse Bases

Fuse bases used with Typower ZILOX fuses according to DIN 43 620, please contact your local Bussmann Sales Representative.