840 Signal Tower KombiSIGN 70


 

 
Signal tower system 70 mm Ø with modular construction.
360° visibility.
Wide range of optical and audible elements.
Elements can be assembled as required.


 






 
TECHNICAL SPECIFICATIONS
 
Dimensions (Diameter x Height): Terminal element: 70 mm x 30 mm
Light element: 70 mm x 65 mm
Audible element: 70 mm x 72 mm

 
Housing: Terminal element: PA fibreglass, high-impact
Capl: PC/ABS-Blend

 
Dome: PC, transparent
Audible and ASI elements: PC/ABS-Blend

 
Fixing: Base mounting
Tube mounting, for tube ø 25 mm
Bracket mounting

 
Socket: Bayonet, B 15 d, for bulb max. 7 W

 
Connection: Screwable connection max 2,5 mm²,
Contact protection according to VDE

 
Cable entry: Cable diameter max. 14 mm

 
Element seal Standard pre-mounted with each module

 
Protection rating: Light elements: IP 54
Audible elements: IP 54
(Order no. 844 123 55 = IP 40)

 
Number of modules possible: max. 5 / max. 10 elements with 2-sided bracket

 
Operating temperature: -20°C to +50°C

 
sound intensity: 105 dB

 
Permanent light element: 12 - 240 V
Bulb not included in assembly
Blinking light element:
24 V =~ 115 V =~ 230 V =~           

Bulb not included in assembly

Starting current: < 0,5 A

 
Flashing light element 12 V = 24 V = 115 V ~ 230 V ~
Flashing frequency 1 Hz 1 Hz 1 Hz 1 Hz
Flash energy 2 Ws 2 Ws 2 Ws 2 Ws
Life duration 4 Mio. flashes      
Current consumption: 195 mA 125 mA 20 mA 35 mA
reduced for AS-Interface:   80 mA    
Starting current: < 0,5 A at 24 V

 
LED-Permanent light element 24 V =~ 115 V ~ 230 V ~        
Current consumption: 45 mA 25 mA 25 mA        
Starting current: < 0,5 mA

 
LED-Blinking light element 24 V =~
 
115 V ~ 230 V ~
Current consumption: 25 mA 25 mA 25 mA
Starting current: < 0,5 mA    
Blinking frequency: c. 1 Hz c. 1 Hz c. 1 Hz

LED-Rotating light element

24 V =~
 
Current consumption: 70 mA
Starting current: < 0,5 mA
Rotation frequency: c. 120 r.p.m.