845 Signal Tower with AS-Interface-Element and additional external voltage


 

 
Signal tower KombiSIGN 50 with AS-interface element is capable of total communication: By simple integration of an AS-interface element the actuators are connected to the networking system actuator-sensor-interface - this reduces complex wiring considerably. This element is to be mounted as the lowermost element in the signal tower just like a light element.
 

 


 





 
TECHNICAL SPECIFICATIONS
 
Dimensions
(Diameter x Height):
52 mm x 67 mm

 
Protection rating: IP 54
 
Operating voltage: 18.5 V ... 31.6 V
 
Current consumption: 50 mA
 
Number of signal elements: 4
 
Type of signal elements: Flashing light elements
LED elements
Buzzer elements
Siren elements

 
IO-Code : 8
 
ID-Code : F
 
Power supply: via bus conduction
 
Reverse battery protection: integrated
 
Watchdog : integrated
 
Terminals : 4, relays
 
On load voltage: additional external voltage:
10 V...30 V=
10V..230 V~

 
Current carrying
cap sum Imax:
1.5 A
 
Short current-
/overload pro:
fuse M 1.6 A
 
Working temperature: -20 °C ...+50 °C